Industrial Chiller Specifications | Industrial Water Chiller Units

What is an industrial chiller ? Industrial chiller is an effective solution to reduce or consume the heat emitted by the machine. If you are in an area with a sandstorm, the outdoor environment continues to be hot +40℃, or something like the arctic where snow freezes all the time, Finding an industrial water chiller to cool your equipment is a very effective way. Because whether water tower or air cooling solution, They are not up to the harsh environment|Equipment Photo of Industrial Chiller

The industrial chiller is a kind of cooling water equipment which can provide constant temperature, constant water flow speed and water pressure. Industrial process chiller is usually a closed loop system, which can provide instantaneous cooling for the factory or lab production process and save water by recirculating cooling.

Industrial chiller system be divided to low temperature chiller and normal temperature chiller in the temperature control. The normal temp is generally controlled within the range of +4 ℃ to +35 ℃. The low temperature water chiller is generally controlled in the range of 0 ℃ to -100 ℃|Equipment Photo of Industrial Water Chiller Units

Industrial Chiller
Model DescriptionEW531S Industrial Chiller
Outlet Water Temp+4℃ ~ +40℃
Refrigerante GasR22, Dupont USA
Cooling Capacity9 kW
Compressor TypeFrance Tecumseh
Air Cooled CondenserFinned Copper Tubes
Evaporator UnitShell and Tube
Chilled Water Flow95 Liters/minute
Chiller Consumption2.95 kW
Power VoltageAC 380V, 50Hz, 60Hz
Medium MaterialClean Water
Main engine adopts compressor imported from France Tecumseh compressor, built-in safety protection. Wewon’s industrial chiller systems are reliable operation, high efficiency and low noise, Energy-saving, long service life.GW531B Industrial Chiller Features
Radiating cold row of air-cooled unit, Arranged by twisted pieces, During the manufacturing process, the secondary flanging and warping piece mechanical tube expansion process and heat exchanger production line are used to ensure high quality and efficiency.
Microcomputer intelligent temperature controller, with high precision digital display, can control water temperature ±1℃. Set the temperature range +4℃ ~ +40℃, The number can be adjusted and set arbitrarily.
Industrial chiller units from Wewon Tech equipped with SUS 304 stainless steel water tank, Built-in automatic water replenishment, automatic temperature control features. The chilling water system adopts bushing type, Inner threaded copper tube, reasonable design, high heat exchange efficiency.
Water chiller system with electrostatic spray shell, European design, beautiful and generous. The exterior panel adopts the form of quick disassembly and installation, which is convenient for use and maintenance.

Wewon Environmental Chambers Co., Ltd. has a wealth of experience in the production of rapid temperature change industrial chillers. This article will make you easier understand the Wewon’s GW531B model industrial chiller’s features and testing performance. If you’re using the temperature controlled chamber and you get a headache from the high heat generated by the machine, Welcome to communicate with our technical engineers, We may help you.

The industrial chiller is divided into water-cooled chiller and air-cooled chiller. The water-cooled chiller must be equipped with cooling tower. Chilled water system is a machine that cools normal water through the chiller’s compressor to a certain temperature to strengthen the cooling process and generate a lot of heat.

related page logoThe Detailed Photo of The Internal Structure of The Machine
related page logoRefrigeration System Details For The Industrial Chillers Units
related page logoThe Cold Water Circulation System of Chiller Units Industrial
related page logoWater Circulation System of GW531B Industrial Water Chiller
Industrial Water Chiller Units
Industrial Water Chiller Units

How does an industrial chiller work ? The main application of air-cooled industrial chiller is in the environment of less impurity dust, poor water quality or water shortage, which need to save space test environment. Industrial water chiller provides high precision constant temperature and frozen water medium for different environmental chambers. GW531B industrial chillers from Wewon provide continuous cooling capacity for continuous improvement of industrial production efficiency.

What is efficiency of industrial chiller ? The air-cooled industrial chiller is not equipped with water tower and is easy to operate and reasonable in design. It is an indispensable companion for modern industrial production. Refrigerants can be selected according to environmental standards of different countries and regions, such as R22, R23, R404A, R134a, R407C and other environmentally friendly refrigerants that do not destroy ozone layer.

What’ the working principle of industrial water chiller ? The industrial chiller system operates through three interrelated systems: water-cycling system, refrigerant circulation system and electric automatic control system. The water recycle temperature of the industrial water chiller should not be higher than +40 ℃. The higher the return water temperature is, the greater the damage to the compressor will be.

● Cooling Water-Cycling System

First, Inject a certain amount of water into the water tank of the refrigeration industrial chiller. The water is cooled by a cold water mechanism cooling system. Then, The low temperature cooling water is sent to the equipment to be cooled by the water pump.

The chilled water from the chiller carries the heat away and returns to the water tank at a higher temperature. Use this method to achieve the cooling effect. The cooling water temperature can be control and adjusted as required. Long-term use can save water. Therefore, the water chiller system is a kind of standard environmental protection and energy saving equipment.

Working Principle of Industrial Water Chiller

● Refrigerant Circulation System

The liquid refrigerant in the evaporator absorbs heat from the water and begins to evaporate. This make a certain temperature difference is formed between the refrigerant and the water. The liquid refrigerant is completely evaporated into a gaseous state and then sucked up and compressed by the compressor (pressure and temperature increase).

Gaseous refrigerants absorb heat through the condenser (air-cooled, water-cooled), Condense into liquid, The evaporator is throttled through a thermal expansion valve (or capillary tube) into a low temperature and low pressure refrigerant, Complete the refrigerant circulation process.

● The Automatic Control System

The electric automatic control system include power system and automatic control section. The power supply part is connected with the demulsifier to supply power to the compressor, fan and pump. The automatic control part includes temperature controller, pressure protection, delay controller, relay overload protection, etc