Rain Spray Test Apparatus Waterproof Rain Test Apparatus UL 50E UL 1598

Rain spray test apparatus is mainly suitable for waterproof performance test and UL waterproof level test of communication equipment, auto parts, outdoor lamps, auto lamps, household appliances, electric cabinet power supplies, outdoor lighting and signal devices. The sample or equipment to be tested may be affected by water intrusion during transportation or use. It is very wise to use the Waterproof Rain Test Apparatus for testing and verification of the sample or equipment being tested. After the sample is tested, it is judged whether the performance of the product meets the requirements through inspection, so as to facilitate product design, improvement, verification and factory inspection.

Rain spray test apparatus from Wewon Tech comply with UL test standards, such as UL50E UL1278 UL484 UL1598 UL3703. The Wewon’s waterproof rain test apparatus conforms to the North American rain test standard, and is suitable for the rain test of products exported to North America. Due to the different batch configuration, the appearance will be different, the actual product shall prevail, Please inquiry to Wewon’s engineers to get the latest equipment structure and product quotation accordingly.

Rain Spray Test Apparatus

Equipment ModelWEW-UL-50E-1598
Equipment DimensionsL:1500*D:600*H2200 mm
Adjust Range of Nozzle400~2000mm (From Ground)
Number of UL Nozzles3 Pieces
Total Water Pressure50~150Kpa
Single Nozzle Pressure34.5Kpa
Number of Pressure Gauges4 Pieces
Equipment Weight85 KGS
Equipment Wheels4 Pieces
UL Spray Nozzles3 Pieces, (From US and Comply with UL)
Water Pipes3 Metres

Rain spray test apparatus from Wewon Environmental Chambers Co., Ltd. is suitable for UL rain test of products, such as UL50E、UEquipment Features
Components of Wewon’s rain test lab equipment: UL rain test device (3 UL nozzles above)
The main part of the device frame is made of formed aluminum material, which is stable in structure and easy to clean.
The nozzle holder for UL rain spray waterproof test equipment is movable and can be raised and lowered freely by the hand crank device.
Rain test apparatus from Wewon Tech adopts the original imported nozzle of UL laboratory, which fully conforms to the UL standard.
The base of the bracket adopts universal casters with brakes, which is convenient to move and fix.
Equipment with SUS high-quality stainless steel pressure gauge is used to display the water spray flow (each nozzle has a corresponding pressure gauge).

Rain spray test apparatus is used to evaluate whether the electronic and electrical equipment, enclosures and seals can ensure the good performance of equipment and components in the rain environment. It can simulate various environments such as dripping, splashing, etc. The realization of fully automatic product operation application of Rain spray test apparatus is the mainstream of today’s social development UL 50E Rain Test Apparatus


The rain spray waterproof test equipment has the functions of self-calibration, self-inspection, self-diagnosis and self-adaptation; it has the data processing capability of complex calculation and error correction; the products with the function of automatically completing the specified measurement tasks can effectively improve the work efficiency. With the rapid development of internationalization and network technology, UL Rain test apparatus is gradually changing to industrial control and intelligent rain test chamber system design.

Wewon Environmental Chambers Co., Ltd. knows that the future Waterproof Rain Test Apparatus will integrate computer technology and cloud computing technology to realize its network and internationalization. Rain spray test apparatus that can be controlled, monitored, maintained and diagnosed remotely will be an important direction for future development.

ANSI Z21.10.3|CSA 4.3Gas-Fired Water Heaters, Volume III, Storage Water Heaters with Input Ratings Above 75,000 Btu Per Hour, Circulating and Instantaneous
CSA 4.3-2004American National Standard/ CSA Standard for Gas Water Heaters Volume IIII, Storage Water Heaters with Input Ratings Above 75,000 Btu Per Hour, Circulating and Instantaneous
ANSI Z21.58 CSA 1.6-2015American National Standard/CSA Standard for Outdoor Cooking Gas Appliances
UL 50EStandard For Safety|Enclosures for Electrical Equipment, Environmental Considerations
UL 82Underwriters Laboratories Inc|Standard for Safety → Electric Gardening Appliances
UL 153Standard for Safety Portable Electric Luminaires
UL 154UL Standard for Safety Carbon-Dioxide Fire Extinguishers
UL 484Standard For Safety|Room Air Conditioners|UL 50E Rain Test Spray Piping and Dimensions
UL 498Standard For Safety|Attachment Plugs and Receptacles
UL 514BFittings for Cable and Conduit|UL 50E Rain Test Spray Head and Dimensions

The ground is flat, the drainage is unobstructed, the ground and walls are waterproof, and floor drains or drains are set.Installation Site for Rain Spray Test Apparatus
The ground bearing capacity is not less than 100kg/m2.
The site for is UL rain spray test apparatus well ventilated.
There is no strong vibration around the rain spray waterproof test equipment.
There are no flammable, explosive, corrosive substances and dust around the UL rain test apparatus.
Appropriate space for use and maintenance is reserved around the rain test apparatus.
The rear side, left and right sides, and top of the equipment: 1000mm.
The front side of the UL rain test apparatus: 2000 mm.
Temperature Range: 5℃~35℃Environmental Request for Temp, Humidity, Water Pressure
Relative Humidity Request: ≤85%
Air Pressure: 86kPa~106kPa
User is required to configure a water source for machine at the installation site, the water pressure is not less than 0.2Mpa, and a 4-point tap is installedWater Source and Supply’s Requirements
The faucet should be no more than 2 meters away from the UL Rain spray test apparatus.

UL 588Standard For Safety|Seasonal and Holiday Decorative Products
UL 1278Movable and Wall or Ceiling – Hung Electric Room Heaters
UL 1573Stage and Studio Luminaires and Connector Strips
UL 1598UL Standard For Safety|Luminaires
UL 1703Standard For Safety|Flat-Plate Photovoltaic Modules and Panels
UL 1741Inverters, Converters, and Controllers for Use in Independent Power Systems
UL 1993Standard For Safety Self-Ballasted Lamps and Lamp Adapters
UL 2201Standard For Safety Carbon Monoxide (CO) Emission Rate of Portable Generators
UL 8750Standard For Safety Light Emitting Diode (LED) Equipment for Use in Lighting Products
UL 60950-1Information Technology Equipment – Safety- Part 1: General Requirements
UL 62368-1Standard For Safety Audio Video, Information and Communication Technology Equipment – Part 1: Safety Requirements

© Copyright 2014-2018. Wewon Environmental Chambers Co., Ltd.