Wewon Tech has developed solar simulation chambers for automobile components customers according to DIN 75 220 test standard. The design of solar simulation chambers from Wewon Tech meets the specific requirements of DIN 75 220 Table 1 for the irradiance spectrum. According to the requirements of the test standard, a sunlight simulation system must be installed to simulate the light aging characteristics of the whole vehicle or component. The metal halide lamps shall be assembled on the rail brackets in the solar simulation unit.
Test engineer can use the DIN 75 220 test to evaluate changes in the performance of parts or vehicles after irradiation, including changes in shape, color, gloss, feel, strength, sealing, and changes in artificial full irradiation, heat/cold and various thermal expansion results under the action of humidity were evaluated. The DIN 75220 test standard is mainly designed for automobile sunlight simulation aging test.
Determination of the ageing characteristics of polymeric automotive structural components in their original structural position and manner of assembly by completing DIN 75 220 test trials. This method is applied to vehicle assembly components or entire vehicles and is therefore particularly suitable for revealing the interaction of various materials within a structural member or between structural members. The light stand is fixed on the top, but the light field can obtain light intensity with uniformity within ±10% at different heights.
Equipment Name | Solar Simulation Chamber → Metal Halide Lamp Test Chamber → DIN 75 220 |
Test Room Size (Liters) | 225L, 408L, 500L, 1000L, ~ 50m3, Accepte the Customized Design |
Temperature Range | -70℃~+150℃ |
Radiation Tempe Range | -20℃~+100℃ |
Temperature Uniformity | ≤2℃ (Under No Light) |
Temperature Deviation | ±2℃ (Under No Light) |
Temperature Fluctuation | ≤1℃ (≤±0.5℃, According to DIN 75 220) |
Heating Time | +20℃~+150℃/45min (No Load) |
Cooling Time | +20℃~-70℃/80min (No Load) |
Humidity Range | 20~95%RH (Under No Light) |
Humidity Range | 20~80%RH (Under Light) |
Humidity Deviation | ±3%(>75%RH), ±5%(≤75%R) |
Irradiation Intensity | 400~1200 W/m2/±10 W/m2 Adjustable |
Spectral Power Distribution | 280~3000 nm → Metal Halide Lamp Test Chamber → DIN 75 220 |
Irradiance Uniformity | ≤10%|Solar Simulation Chamber |
Spectral Distribution | MIL-STD-810 Method 505.4, DIN75220, GJB150.7A, |
Inside The Light Source | Full Spectrum Metal Halide Lamps |
Temperature Controller | Chinese color touch screen + PLC controller (control software self-developed) |
Low Temperature System | The unique design meets the automatic operation of the compressor in the full temperature range |
Refrigeration Compressors | Imported Full/Semi-Hermetic Compressor |
Cooling Method | Air Cooling (Water Cooling Option) |
Humidification Water | Distilled or Deionized Water |
Security Measures | Leakage, Short Circuit, Over Temperature, Water Shortage, Motor Overheating, Compressor Overpressure etc. |
Standard Device | Sample Shelf (Two Sets), Observation Window, Lighting, Cable Hole (50mm ~ 100mm), With Casters |
Power Supply | AC 380V, AC 440V, 50Hz 60Hz, 3 Phase + Ground Wire |
Equipment Material | Cold-Rolled Steel Plate Electrostatic Spray (SETH Standard Color) |
Inner Wall Material | SUS304 Stainless Steel Plate |
Insulation Materials | Rigid Polyurethane Foam |
● | Multi-variable control, users can choose light intensity feedback or black body temperature feedback control mode. | Equipment Features |
● | Imported metal halide lamps ensure no drift in chromatography during the service life. Imported power supply ensures accurate power output and can effectively prolong lamp life. | |
● | The light stand can be raised and lowered, the automatic positioning motor system, and the angle of the light stand can be adjusted. It can be designed as a movable light stand according to customer needs. | |
● | Metal lampshade, equipped with filter glass, easy to disassemble structure, easy to replace the lamp. Solar simulation chambers from Wewon Tech are also suitable for solar radiation testing of aircraft, unmanned surveillance equipment. |
During the test, different test methods and different test periods can be selected according to different use conditions. According to the test standard of MIL-STD-810 Method 505.4, the first procedure is the cyclic test and the second procedure is the steady state test. Program 1 focuses on the effects and influences produced by solar radiation; Program 2 focuses on photochemical effects produced by solar radiation. Wewon’s solar simulation system comply with the test standard, such as DIN 75 220, MIL-STD-810 Method 505.4, GJB 150.7A-2009