Functional Mode | Detailed Explanation Of Functions | Function | Setting Method |
H001/ H000 Control Delay | H001: When the pressure reaches the action point, the controller does not act immediately, the delayed action, and the time of delayed action can be set. | Setting the control delay can prevent the motor from starting frequently due to unstable pressure in the tube. | After pressing the key to switch H001 to H000, the screen displays “0010”, which is represented as 10 seconds, change this value by (▲)(▼) keys, the unit is seconds, press the set key to save and jump out. |
P001 / P000 Parameter Protection | Function on: Press on anything other than the key
Thee key, the screen will display “—“, at this time you need to enter a password to set parameters such as upper and lower limits.
| Protect the upper limit, lower limit and other parameters set by the engineering personnel from being modified. | When “—” is displayed, enter the password by the (▲) key, and the SET key shift, and enter the password “1111” “, press the setting button briefly to set the parameters. |
匕001/匕000 Reverse Control | Function on: normally open when the pressure is lower than the lower limit, normally closed when the pressure is above the upper limit. | Implement reverse control function. | Turn the function on or off by increasing the key (▲) / decreasing the key (▼). |
S001 /S000 Automatic Pressure Check | Function on: After the relay is closed, the controller will automatically disconnect the relay and display “E–1” on the screen if the pressure change is not detected for 3 minutes. | Avoid the pressure caused by water source draining, water stoppage, pipeline leakage does not reach the upper limit, the pump is idling, dry burning. | When the function code is displayed, turn the function on or off by increasing the key (▲) / decreasing the key (▼). |
F001 / F000 Water Shortage Protection | When the water pressure is lower than the set water shortage protection value, it is considered that there is no water in the pipe, and the motor is turned off, and E—-F is displayed. | Same as above | After switching F001 to F000, the screen flashes and displays the water shortage protection value, which is changed by the (▲)(▼) key. |
L001/L000 Detection Time | When the water protection function is activated, if the pressure does not reach the water shortage protection pressure value within the set detection time, the relay is disconnected and E—-F is displayed. | Same as above | The default is 20 seconds, you can enter the parameter and change this value by (▲) (▼) key. When the water shortage protection function is turned off, the function is automatically turned off. |