VOC Online Monitoring System for Volatile Organic Compounds VOCs Analysis

Volatile Organic Compounds, referred to as “VOC” is an important reason that affects the air quality in the car. VOCs mainly include alkanes, olefins, aromatic hydrocarbons, aldehydes or ketones and other substances, with a special pungent odor, and some of them have been classified as carcinogens, such as vinyl chloride, benzene, polycyclic aromatic hydrocarbons, etc., and some VOCs also damage the ozone layer. effects such as chlorofluorocarbons and hydrochlorofluorocarbons. Nowadays, automobiles have entered thousands of households, and the problem of air pollution inside automobiles has also become a hot spot that consumers are generally concerned about.

Automobile associations and related agencies in various countries have formulated in-vehicle air standards and requirements in order to control the air quality in the car. World-renowned car companies have also formulated their own corporate standards to control the air quality in the car. It is also for this reason that Wewon Environmental Chambers Co., Ltd. has equipped a professional VOC online monitoring system for volatile organic compounds VOCs analysis and monitoring purpsoe for VOC formaldehyde emission test chambers.

VOC Online Monitoring System
Equipment NameVOC Online Monitoring System
Equipment ModelWEW-VOC-GP005
Measurement ChannelUp to 6 sensor measurement channels
①3 non-split infrared (NDIR) measurement principle sensor channels;
②3 other measurement principle sensor channels (electrochemical principle, non-dispersive infrared (NDIR) principle, PID photoion principle, catalytic combustion principle sensor channel, optional)
Measuring Principle & Measuring Gas● Non-spectrographic infrared (NDIR) measurement principle
Such as carbon dioxide (CO2), methane (CH4), carbon monoxide (CO), sulfur dioxide (SO2), nitric oxide (NO) and other gases;
● Electrochemical measurement principle
Such as oxygen (O2), carbon monoxide (CO), hydrogen (H2), ammonia (NH3), sulfur dioxide (SO2), hydrogen sulfide (H2S), nitrogen oxides, hydrogen fluoride, chlorine, etc. in the air;
● Non-dispersive infrared (NDIR) principle
Such as carbon dioxide (CO2), methane (CH4), sulfur hexafluoride (SF6), propane (C3H8), etc.;
● PID Photoion Principle
Such as VOC, TVOC, benzene, methylbenzene, xylene and other organic volatile compounds;
● Catalytic combustion principle
Such as combustible gas, methane, hydrogen and other combustible gases;
Measuring RangeDepending on the specific gas to be detected, the factory label shall prevail. (0-50ppm recommended)
0-1ppm、5ppm、10ppm、20ppm、50ppm、100ppm、200ppm、500ppm、1000ppm、2000ppm、5000ppm、10000ppm、50000ppm、100%Lel 、0-2%Vol、5%Vol、10%Vol、30%Vol、100%Vol in optional
Resolution0.01 ppm or 0.001ppm(0~1ppm|0.01ppm(0~100ppm|0.1ppm(0~1000ppm| 1ppm(1000ppm and Above| 0.1%Vol(0~100%Volor 0.01%Vol(0~100%Vol|0.01% Lel(0~100% Lel
CombinationTwo in one, three in one, four in one, five in one, six in one optional
Sensors with two-in-one configuration can be turned on or off independently to avoid gas interference and prolong sensor life
Sampling Method①Circulation type – online continuous detection, circulation detection method;
②Suction type – equipped with built-in or external air pump to realize the detection method of pump suction type (air pump optional);
Installation Method①Desktop, rack type;
②Wall-mounted installation, with mounting bracket
Indication Error≤±3% FS (higher accuracy is required according to sensor performance)
Repeatability≤±1%
Zero Drift≤±1%(FS/ Year)
Response Time≤25 seconds , (higher requirements are based on sensor performance)
Recovery Time≤30 seconds (higher requirements based on sensor performance)
Preheat TimeMore than 120 seconds (depending on different sensor configurations)
Power Supply220VAC +10%,-15% 50Hz ±5Hz
Equipment FuseRated Current: 10A, Dimensions: 5mm*20mm
Intake Flow(0.5~0.8L)/min(Fluctuation in traffic ≤0.02L/min
Environmental Pressure86kPa~106kPa
Ambient Temperature-20℃~+55℃ Standard Conditions|-40℃~+70℃ Min & Max Conditions
Environment Humidity10%~95%RH(no condensation
The Main MaterialSPCC+Aluminum profile
In order to support the development of test methods and reference materials for volatile organic compounds (VOC) emissions from building materials and furnishings, Engineering laboratory US maintains a number of environmental chambers for measuring these emissions. These VOC/formaldehyde emission test chambers can be operated at temperatures up to 120 °C for the smaller volumes and 250 °C for the larger, which can be used to accelerate the emissions process for some compounds.

GS 97014-3 calls for testing automotive interior trim in a small thermostatic emissions chamber. This instrument’s 1m3 chamber allows our VOC specialists to accommodate larger samples, such as components and subassemblies, than other methods that can only support small material specimens. GS 97014-3 Testing ATS chemists seal the specimen inside the chamber after a preconditioning period and provide a constant internal airflow to capture VOCs emitted during the test duration; they then analyze these air samples using Gas-Chromatography/Mass-Spectroscopy (GC/MS) to identify and measure any present VOCs.
related page logoTesting and Measuring Apparatus for volatile organic compounds (VOCs) Analysis and Monitoring|Agilent 7890A gas chromatograph with flame-ionization detector (FID)|Agilent 5975C Inert selective mass detector
related page logoGas Chromatographs Supplier → AMETEK MOCON|Continuously monitor single or multiple gas components using Baseline’s industrial-grade Process Gas Chromatographs.
related page logoTotal Hydrocarbon Analyser → The Flame-Ionisation-Detector 2010 T measures Total HydroCarbon (THC) in a wide range of applications like catalytic- and thermal oxidiser plants, waste gas processing plants, room and environmental air, solvent recovery plants and vehicle exhaust gases.By it`s little weight and it`s compact dimensions, he is especially made for daily changing measuring points or shorttime measurings campains.
related page logoChroma FID – Volatile Organic Compounds (VOC) Analyzer|A GC/FID instrument for automatic, continuous analysis of Volatile Organic Compounds (20 ppb to ppm). The ChromaFID is a gas chromatograph dedicated to the analysis of VOC’s from 20 ppb to ppm levels. The analyser enables the continuous monitoring of the concentration of VOC compounds from C1 to C12.
related page logoGas Chromatographs Supplier →Gas chromatography (GC) coupled with a PID detector. VOC monitor QAL1 certified to EN 14662-3, the newest standard for benzene measurement
related page logoGas chromatograph (FID) from SpeeTech is a high-performance CG-FID gas chromatograph designed and manufactured using electronic information technology, combined with mature detection technology and gas path technology. This continuous VOC monitoring system meets the online monitoring of non-methane total hydrocarbons, total hydrocarbons, VOCS, benzene series, CH4, etc. SD-9000A gas chromatograph uses a hydrogen flame ionization detector (FID)
related page logoGC-2010 Plus High-end GC → The GC-2010 Plus enables reliable, high-precision trace analysis with high repeatability, utilizing detectors such as FID and FPD that feature best-in-class sensitivity. In addition, rapid oven cooling and backflush technology shorten analysis time greatly for significant improvements in productivity.
Output Signal①Three-wire 4-20mA current signal output, can be connected to various alarm controllers, PLC, DCS and other control systems
②RS-485 digital signal output, connect RS232 adapter card to view the stored data on the computer
③4 groups of relay high and low alarm switch output, 1 public relay output: passive contact, capacity 30V 1A, 125VAC 0.5A
④Voltage signal output: 0-5V, 0-10V signal output can be set by yourself (optional)
Signal Transmission Method①Three-core (four-core) shielded cable transmission: up to 1000 meters to 2000 meters (single core 1 square shielded cable)
②Network port TCP/IP transmission: support TCP/IP protocol, network cable transmission within 90 meters, long-distance real-time transmission through networking (optional)
③Optical fiber transmission: The longest transmission distance is 20 kilometers to 40 kilometers (optical cable single-mode multi-core transmission, must be equipped with optical fiber MODEM), can be networked (optional)
④Short-distance RTU433 wireless transmission: The transmission distance is 0 to 2 kilometers, depending on the transmission power and site environment (optional)
⑤GPRS wireless transmission: no distance limit, built-in module, through mobile, China Unicom or telecom signal transmission, with SMS reminder notification function (optional)
Alarm MethodExternal sound and light alarm, alarm sound: < 90 decibels
Alarm PointA1 alarm value, A2 alarm value; TWA alarm value, STEL alarm value can be set independently
Controller Display5 inch TFT touch LCD color LCD screen, 800×480 dot matrix LCD
Operation Method5 inch LCD touch screen touch operation + key auxiliary operation
Equipment ButtonMain interface + Lock Screen + Reset
BacklightManual, automatic when alarm
Direct ReadingMeasured value, ambient temperature and humidity, date and time, maximum value, minimum value
Data RecordAutomatic data storage, 1-6 sensor storage intervals can be customized, can continuously store 300,000 sets of data with date and time, optional micro TF memory card, can store more than 10 million sets of data
Data DownloadSupport USB and RS232 serial port measurement data download
Data PrintingSupport micro portable printer serial port printing (optional)
Equipment CalibrationLevel 2 to Level 3 target point full software calibration function, can set calibration value, one-key zero adjustment
Calibration Standard Gas RequirementsZero standard gas: 99.999% N2 (nitrogen)
Full-scale calibration gas: 85%-110% of the full scale of the measured gas
The third point calibration gas: 35%-75% of the full scale of the measured gas
Protection ClassIP42
Operating ModeUser mode, administrator mode 2 operating modes to choose from
Equipment DimensionsStandard 19″ Chassis,W480mm×D310mm×H130mm
Equipment Weight25 KGS
Quality Assurance Warranty period is one year, and the maintenance is free during the warranty period.
related page logoTesting and Measuring Apparatus 1 → Portable Total Hydrocarbon Analyzer → VOC online monitoring system for volatile organic compounds VOCs Analysis and Monitoring
related page logoTesting and Measuring Apparatus 2 → Gas Sampler and Sample Changer → VOC online monitoring system for volatile organic compounds VOCs Analysis and Monitoring
related page logoTesting and Measuring Apparatus 3 → Hydrogen Generator → VOC online monitoring system for volatile organic compounds VOCs Analysis and Monitoring
related page logoTesting and Measuring Apparatus 4 → Heat Exchanger (inside has tubes) and on the Outside Glass that is Fogged and can Visually see the Effect of Temperature → VOC online monitoring system for volatile organic compounds VOCs Analysis and Monitoring
Most of the volatile organic compounds in the car come from the paint after the car paint. In order to reduce the health hazards caused by the material VOC to the human body, China has vigorously developed environment-friendly paint products in recent years. , Consumption tax is levied in the production, outsourced processing and import links. Only coatings with a volatile organic compound content below 420 g/L (inclusive) in the construction state are exempt from consumption tax. 1

VOC Online Monitoring System for Volatile Organic Compounds VOCs Analysis

When the concentration of VOC is too high, it is easy to cause acute poisoning. In mild cases, headache, dizziness, cough, nausea, and vomiting may occur; in severe cases, convulsions may occur, and it will damage the human liver, kidneys, brain and nervous system. Medical research has proved that pregnant women living in the environment of volatile organic compounds have a much higher probability of fetal malformations than ordinary people, and may have an impact on the future intellectual development of their children.
related page logoThe Manufacture and Suppliers for VOC Formaldehyde Emission Test Chamber|VOC Online Monitoring System for Volatile Organic Compounds VOCs Analysis
related page logoThe Manufacture and Suppliers for VOC Formaldehyde Emission Test Chamber|VOC Online Monitoring System for Volatile Organic Compounds VOCs Analysis
related page logoThe Manufacture and Suppliers for VOC Formaldehyde Emission Test Chamber|VOC Online Monitoring System for Volatile Organic Compounds VOCs Analysis
related page logoThe Manufacture and Suppliers for VOC Formaldehyde Emission Test Chamber|VOC Online Monitoring System for Volatile Organic Compounds VOCs Analysis
related page logoThe Manufacture and Suppliers for VOC Formaldehyde Emission Test Chamber|VOC Online Monitoring System for Volatile Organic Compounds VOCs Analysis
related page logoThe Manufacture and Suppliers for VOC Formaldehyde Emission Test Chamber|VOC Online Monitoring System for Volatile Organic Compounds VOCs Analysis
related page logoThe Manufacture and Suppliers for VOC Formaldehyde Emission Test Chamber|VOC Online Monitoring System for Volatile Organic Compounds VOCs Analysis
related page logoThe Manufacture and Suppliers for VOC Formaldehyde Emission Test Chamber|VOC Online Monitoring System for Volatile Organic Compounds VOCs Analysis
related page logoThe Manufacture and Suppliers for VOC Formaldehyde Emission Test Chamber|VOC Online Monitoring System for Volatile Organic Compounds VOCs Analysis
The Wewon’s volatile organic compounds (VOCs) online monitoring system is configured with up to 6 sensor measurement channels, 3 non-dispersive infrared (NDIR) measurement principle channels, 3 other measurement principle channels (electrochemical principle, non-dispersive infrared (NDIR) principle, PID photoion principle, catalytic combustion principle sensor channel optional).Equipment Features
Multiple gas sensors can be opened or closed independently, effectively avoiding the cross-interference between the detected gases and prolonging the service life of the sensors.
The VOCs online monitoring system is equipped with a large 5-inch touch TFT-LCD color liquid crystal control screen, which is simple and convenient to operate.
The built-in filter and regulating valve can be replaced without disassembly on site, which is suitable for 24-hour online monitoring of industrial sites.
Standard 19-inch chassis, rack-mounted, desktop, wall-mounted optional, suitable for various industrial site monitoring.
Detailed measurement data display, measurement value, concentration unit, ambient temperature, humidity, maximum and minimum values are clearly displayed.
VOC online monitoring system for volatile organic compounds VOCs analysis and monitoring using embedded 32-bit ultra-low power microprocessor, the detection error is small and the resolution is high.
Built-in temp and humidity sensor, real-time display of ambient temperature and humidity.
Intelligent temperature and humidity and zero point compensation algorithm, full software automatic calibration function of target points from level 2 to level 3 or above, to ensure the accuracy of the measurement results. automatically detect the working status of each sensor and components when powered on.
Support free switching between PPM and mg/m3, %VOL and mg/L concentration units.
Real-time data transmission, can accurately issue local and remote wireless alarm notification in various alarm methods (optional).
Automatic layout according to the number of sensors. automatic data storage, storage interval can be customized, can continuously store 300,000 sets of data with date and time, optional micro TF memory card, can store more than 10 million sets of data.
The short-distance wireless transmission method or the unlimited-distance GPRS wireless transmission method can transmit the real-time detection data and alarm status to the security center (optional) through the built-in wireless module function.
VOC online monitoring system from Wewon Tech support USB and RS232 serial port measurement data download; support micro portable printer serial port printing.
Principle and Application of PID Photoionization Detector What is a Hydrogen Flame Ionization Detector (FID) ?
The PID Photoion Detection Working Principle Explanation What’s Principle Of Gas Chromatograph FID Monitoring System
Online Monitoring System Detection Method PID Detection Method VOC Online Monitoring System and Gas-Chromatography Detection
Wewon’s VOC monitoring system is used for environmental monitoring such as atmospheric and pollution source emissions. It is used for industrial process control of petroleum, chemical industry, power station, etc., and it is specially used for gas analysis and detection of mud logging instrument. It is used in the fields of agriculture, medical care and scientific research and experiments. Determination of gas content in various combustion tests of waste incineration and landfill. VOCs online monitoring system also can be used for air gas monitoring for public places.
Principle of infrared gas detection. Non-dispersive infrared spectroscopy gas concentration detection technology.Measurement Principle
Non-spectrographic infrared (NDIR) sensors are mostly used in the field of gas analysis as a spectral detection method. It is mainly composed of infrared light source, gas chamber, wavelength filter and infrared detector. The gas is introduced into the gas chamber by pumping, and the gas concentration is specified according to the gas.
The corresponding absorption features on the infrared spectrum of the wavelengths are detected using the electro-optical modulation relationship.
Because all measured gases absorb infrared radiation in a different spectral range, it is called a “fingerprint”, thus ensuring selectivity and reducing cross-interference. The processing of the signal fully considers the influence of temperature and drift, and an easy-to-use concentration signal is obtained through compensation calculation.
Please enter your email, so we can follow up with you.